Type number Ydd-350 biological sample bank liquid nitrogen tank
Parameters
model YDD-350
Liquid nitrogen volume at the bottom of the tray fifty-five
Volume of sample storage space (L) two hundred and sixty-two
Geometric volume of tank (L) three hundred and seventy-seven
Effective volume of tank (L) three hundred and fifty
Tank diameter (mm) three hundred and twenty-six
Internal effective height (mm) six hundred
Total tank height (mm) one thousand three hundred and twenty-six
Empty weight of tank (kg) two hundred and nineteen
Tank operation height one thousand two hundred and sixty-three
        Liquid nitrogen tank of biological sample bank It is mainly used in the construction of stem cell bank and human sperm bank. liquid nitrogen tank Advanced evacuation technology, thermal insulation technology and high vacuum permanent holding technology are adopted to ensure the safe storage of fault free samples, good uniform temperature characteristics and minimum liquid nitrogen consumption. The temperature difference in the whole storage area is less than 10 ℃ and the lowest temperature on the top of the freezing rack can reach - 190 ℃.

model YDD-350 Liquid nitrogen tank
Liquid nitrogen volume at the bottom of the tray fifty-five
Volume of sample storage space (L) two hundred and sixty-two
Geometric volume of tank (L) three hundred and seventy-seven
Effective volume of tank (L) three hundred and fifty
Tank diameter (mm) three hundred and twenty-six
Internal effective height (mm) six hundred
Total tank height (mm) one thousand three hundred and twenty-six
Empty weight of tank (kg) two hundred and nineteen
Tank operation height one thousand two hundred and sixty-three
Full load total weight (kg) 502 
Door width requirement ≥ mm eight hundred and ninety-five
Daily evaporation rate% one point five five
supply voltage 220VAC、24VDC
Maximum storage quantity of 0.5ml frozen tube
Quantity of 0.5ml standard frozen tube sixteen thousand and nine hundred
Quantity of 5 × 5 0.5ml bucket four
Quantity of 10 × 10 0.5ml bucket twelve
Quantity of 5 × 5 boxes fifty-two
10 × 10 box quantity one hundred and fifty-six
Layers of 0.5ml bucket thirteen
Size of 5 × 5 0.5ml frozen box 76*76*40
5 ml 10.0 × 10 134*134*40
Size of 5 × 5 0.5ml freezer 82*84*42
Size of 10 × 10 0.5ml freezer 142*144*42
Maximum storage quantity of 2ml inner rotating frozen tube
Quantity of 1.2,1.8,2ml inner rotating frozen tubes thirteen thousand
Quantity of 5 × 5M3 pail four
Quantity of 10 × 10 m3 bucket twelve
Quantity of 5 × 5 boxes forty
10 × 10 box quantity one hundred and twenty
Layers of square bucket ten
Size of 5 × 5.2ml frozen box 76*76*54
Size of 10 × 10 2ml frozen box 134*134*54
Size of 5 × 5.2ml freezer 82*84*56
Size of 10 × 10 2ml freezer 142*144*56
Maximum storage quantity of 2ml sample frozen box
Quantity of 2ml external rotating frozen tube five thousand seven hundred and sixty
Quantity of sample freezing rack eighty
Number of sample frozen boxes seven hundred and twenty
Layer number of sample frozen shelf nine
Frozen box size 161*58*18
Frozen shelf size 163*62*23
The maximum quantity of 5 ml storage tube
Quantity of 5ml frozen storage tube (dwarf type) three thousand seven hundred and forty-four
Quantity of 3 × 3.5ml bucket four
Quantity of 6 × 6.5ml square pail twelve
Quantity of 3 × 3 frozen boxes thirty-two
Quantity of 6 × 6 frozen boxes ninety-six
Layers of 5ml bucket eight
Size of 3 × 3.5ml frozen box 76*76*67
Size of 6 × 6.5ml frozen box 134*134*67
Size of 3 × 3.5ml freezer 82*84*70
Size of 6 × 6.5ml freezer 142*144*70
Maximum storage quantity of 5ml slender frozen tube
Quantity of 5ml frozen storage tube (slender type) five thousand three hundred and sixty
Quantity of 5 × 5.5mL bucket four
Quantity of 9 × 9 5ml bucket twelve
Quantity of 5 × 5 frozen boxes twenty
Quantity of 9 × 9 frozen boxes sixty
Layers of 5ml bucket five
Size of 5 × 5.5mL frozen box 76*76*100
Size of 9 × 9.5ml frozen box 134*134*100
Size of 5 × 5.5mL freezer 82*84*102
Size of 9 × 9.5ml freezer 142*144*102
Maximum storage quantity of straw
Quantity of 0.5ml fine tube (wheat tube) one hundred and eleven thousand three hundred and twelve
25 ml of straw two hundred and fifty-four thousand five hundred and ninety-two
Number of round lifting cylinders fifty-two
Number of round lifting cylinders eight
Number of round lifting cylinders twenty-eight
Layers of round lifting cylinder four
Floor height one hundred and thirty-five

Product standard:
National standard: GB / T 14174-2012

The liquid nitrogen tank of biological sample bank is mainly used in the construction of stem cell bank and human sperm bank. The liquid nitrogen tank adopts advanced evacuation technology, heat insulation technology and high vacuum persistent maintenance technology to ensure the safe storage of fault free samples, good and uniform temperature characteristics and minimum liquid nitrogen consumption. The temperature difference in the whole storage area is less than 10 ℃ and the lowest temperature on the top of the freezing rack can reach - 190 ℃.

Application range:
It is suitable for long-term liquid nitrogen immersion (vaporization) preservation of large quantities of biological samples such as stem cells, plasma, semen, embryos, various tissues and organs.
 
Product features:
 
① Compatible with gas and liquid storage modes;
② A variety of capacity options to meet your storage needs to the maximum extent;
③ More samples are stored in the unit area to reduce the storage cost;
④ Excellent temperature uniformity and stability;
⑤ Excellent temperature stability after opening cover;
⑥ Advanced temperature and liquid level monitoring and alarm system can be connected to remote monitoring;
⑦ Automatic supply liquid nitrogen system, safe and labor-saving;
⑧ The microprocessor control system can save the operation data permanently;
⑨ One button defogging function, easy to find and take samples;
⑩ A number of humanized design, comfortable operation;
⑪ The cover can be locked to ensure the sample safety;
⑫ Integrated folding steps and auxiliary worktable are provided as standard;
⑬ The products meet CE quality certification;
 
 
Product advantages:
 
High density storage
Compared with the similar products, it occupies a small area and stores more samples, which not only saves space, but also reduces the storage cost per unit sample;
 
Excellent temperature uniformity
Vacuum heat insulation stainless steel box structure, high vacuum coverage, to ensure excellent insulation and insulation performance;
 
 
Stable opening temperature
Innovative lid and neck offset small opening excellent design, can greatly reduce the liquid nitrogen volatilization rate. Even if the cover is opened for a long time, the temperature inside the box can be kept stable, and the temperature in the box can not be higher than - 150 ℃ within 48 hours;
 
 
Advanced temperature monitoring system
The monitoring system based on microprocessor and dual platinum resistance temperature probe can display the highest and lowest temperature in the box in real time, with an accuracy of ± 1 ℃. Users can set the alarm point by themselves, with alarm mute option;
 
 
 
Automatic filling liquid nitrogen and liquid level monitoring system
The liquid level monitoring system based on differential pressure sensor can display the liquid level height in real time to ensure the safety and reliability of liquid nitrogen automatic filling process. The 10 inch LCD touch screen can display: top temperature, bottom temperature, liquid level height and operation status and other parameters.
 
 
Hot gas bypass
The hot gas bypass can remove the room temperature nitrogen in the pipeline before liquid nitrogen injection, so as to ensure that only ultra-low temperature liquid nitrogen is injected into the tank, which avoids the temperature fluctuation in the liquid nitrogen tank during the liquid filling process, affecting the sample safety, and reducing the additional liquid nitrogen consumption.
 
 
Multiple humanized design
The stainless steel auxiliary worktable can be used for temporary placement of the frozen storage rack to speed up the sample taking and placing; the integrated folding step reduces the operation height and is convenient and labor-saving. The spare opening of the internal rotating tray is convenient to find the sample dropped accidentally.
Bande liquid nitrogen tank series products provide one year free after-sales service
Five year vacuum warranty.
Tel: 010-80204245
Mobile phone: 15611258074
Q Q: 2678388834
Email: 2678388834@qq.com
Address: Anshun South Road, Huangcun, Daxing District, Beijing
shrink
  • Telephone consultation

  • 010-80204245
  • Wechat consulting